Associated
Press News Article - This article deals with UV lights added to Air
Vents, however we know that any Air Sanitizer /
Air Filtration system with UV added to its system increases its healthier air
effectiveness. We do offer these Air Vent systems (see below) as part of our
Purest Filters healthier living products.
Click here to view this AP article
  
Hygeaire
uv
indirect air disinfection units
-
Units are constructed of tough, corrosion-resistant 304
Stainless Steel to insure long life
- Destroys harmful
bacteria, mold and viruses in the air that are carried
into the ultraviolet field
- Uses baffles to
direct rays to the upper portions of a room
- Upper room portion
must be unoccupied; proper precautions must be
taken when in operation
Application: hospitals, laboratories, clean rooms,
operating rooms, ICU's, burn centers, doctors office,
homeless shelters, methadone clinics, TB clinics,
detention centers, kennels, dairy plants, etc.
Advantages
of the Hygeaire
uv indirect air disinfection units
EFFECTIVE relatively
efficient due to long unobstructed path of the
ultraviolet rays
ECONOMICAL equipment
requires little power to operate
EASY simple
operation and maintenance
AUTOMATIC continuous
disinfection without special attention or measurements
LOW MAINTENANCE
annual lamp replacement and periodic cleaning is all
that is required.
Uses and Applications for the
Hygeaire
uv indirect air disinfection units
The
Hygeaire
principal application of germicidal ultraviolet has been
the use of upper room air disinfection fixtures to
purify the upper room air in occupied spaces in order to
reduce the risk of cross infection and exposure of
occupants to infectious airborne microbes. These
fixtures are designed to project the ultraviolet rays
across the upper room air thereby destroying bacteria
and viruses that are carried into the ultraviolet field
by convection currents or air circulation.
It is an important requirement when applying Indirect
Germicidal ultraviolet irradiation to upper air to keep
the radiation in the occupied level (below 6-1/2" feet)
within acceptable limits (0.2 micro watts per square
centimeter for an eight-hour exposure is a standard set
by the American Conference of Governmental Industrial
Hygienists), so mounting in the appropriate position is
essential for safe use.
|
Applications include protection of personnel
and patients from airborne infection: |
Hospitals
Laboratories
Clean Rooms
Operating Rooms
ICU's
Burn Centers
Doctor and Dentist Office
Pharmaceutical Production |
Homeless Shelters
Methadone Clinics
TB Clinics
AIDs Clinics
Nursing Homes
Schools and Colleges
Business Offices
Prisons and Jails |
Detention Centers
Animal Husbandry
Kennels
Veterinary Facilities
Food Manufacturing Plants
Dairy Plants
Bakeries
Meat Processing Plants |
Features of the
Hygeaire
uv indirect air disinfection units
ELECTRONIC BALLAST
Surelite
Electronic Ballast is a
state-of-the-art electronic ballast
for operation of ultraviolet lamps.
Surelite
offers these advantages over
conventional ballasts:
deliver higher ultraviolet lamp
output
instant starting
eliminate "stroboscopic effect"
smaller and lighter |
operate cooler for longer life
versatile... each operates a
wide range of lamps
save energy through higher
efficiency
provide silent operation |
|
|
GERMICIDAL LAMPS
Genuine Ster-L-Ray
Slimline Germicidal Lamps are instant starting
and provide the utmost in quality, sustained output and
longevity. Approximately 95% of the ultraviolet energy
emitted from Ster-L-Ray
Germicidal Lamps is at the mercury resonance line of 254
nanometers. This wavelength is in the region of maximum
germicidal effectiveness and is highly lethal to virus,
bacteria and mold spores.
LAMP HOLDERS
Steadfast
lampholder These sets include a stationary and a
spring-loaded telescopic holder that holds a sinlge pon
lamp securely. The spring loaded feature on one end
facilitates convenient quick and easy lamp changes.
|
STAINLESS STEEL
The unit is manufactured in Type 304 stainless steel
for an attractive finish, unparalleled strength and
durability. |
|
POLISHED REFLECTOR
Interior surface has polished highly
reflective surface to maximize ultraviolet intensity
within the chamber. |
|
LOUVERS Louvers
unique construction to direct ultraviolet rays to
the upper portion of the room. |
|
INTERLOCK SAFETY SWITCH
The interlock safety switch is a standard
feature that disconnects power to the unit when the
access panel is removed for lamp replacement. |
Principle Operation and Specifications of the
Hygeaire
uv indirect air disinfection units

|
Model |
Model
Number |
Volts/Hertz |
Lamp |
Total Ultraviolet
Output |
Ballast |
Dimensions |
Rated Average
Lamp Life |
|
Length |
Width |
Height |
|
LIND24-EVO |
40-125A |
120v 50/60 Hz |
05-1348 |
8.5 Watts |
10-0056B |
24" |
4-1/2" |
7-7/8" |
10,000 Hours |
|
LIND24-EVO |
40-0188 |
220v 50/60 Hz |
05-1348 |
8.5 Watts |
10-0055B |
24" |
4-1/2" |
7-7/8" |
10,000 Hours |
|
LIND24-EVO-2PM |
40-126A |
120v 50/60 Hz |
05-1348 (2) |
17 Watts |
10-0056B (2) |
24" |
9" |
7-7/8" |
10,000 Hours |
|
LIND24-EVO-2PM |
40-0187 |
220v 50/60 Hz |
05-1348 (2) |
17 Watts |
10-0055B (2) |
24" |
9" |
7-7/8" |
10,000 Hours |
|
  
SaniLight
uv air and surface irradiating fixtures
-
Units are constructed of tough, corrosion-resistant 304
Stainless Steel to insure long life
- Irradiates room
air and exposed surfaces with direct germicidal
ultraviolet rays
- Very effective due
to the long, unobstructed path of the rays
- For ceiling or wall mount in unoccupied
areas, or when proper precautions are taken
Applications: laboratories, clean rooms, operating
rooms, etc.
Advantages
of the
SaniLight
uv indirect air disinfection units
EFFECTIVE
virtually all microorganisms are susceptible to
SaniLight
disinfection
ECONOMICAL equipment
cost is generally less than other alternatives
SAFE no danger of
overdosing and no chemicals to contend with
FAST disinfects both
air and exposed surfaces in seconds
EASY low maintenance
and annual lamp change is all that is required
AUTOMATIC continuous
or intermittent disinfection without special attention
VERSATILE various
models available to accommodate most applications
Features of the
SaniLight
uv air and surface irradiating fixtures
STER-L-RAY
Slimline Germicidal Lamps are instant starting
and provide the utmost in quality, sustained output and
longevity. Approximately 95% of the ultraviolet energy
emitted from STER-L-RAY
Germicidal Lamps is at the mercury
resonance line of 254 nanometers. This wavelength is in
the region of maximum germicidal effectiveness and is
highly lethal to virus, bacteria and mold spores.
Steadfast
Lamp Holder sets include a stationary and a
spring-loaded, telescopic holder, which hold a single
pin lamp securely. The spring-loaded feature on one end
facilitates convenient, quick and easy, lamp changes.
Surelite
Electronic Ballasts are state-of-the-art
electronic ballasts developed specifically for the
operation of ultraviolet lamps.
Surelite
instant start ballasts are smaller, lighter,
more efficient and operate cooler than magnetic
ballasts. These ballasts are silent and provide higher
lamp output.
The Stainless Steel housing provides unparalleled
strength, durability and beauty. The attractive brushed
finish stands up to even the harshest environments.
The finish is polished to maximize
Specifications of the Standard Models
of the
SaniLight
uv air and surface irradiating fixtures
|
Model |
Lamp |
Total Ultraviolet
Output 1 |
|
Dimensions |
|
Rated Average
Lamp Life |
|
Length |
Width |
Height |
|
D 12-1S |
05-1500 |
3.1 Watts |
13-1/4" |
5" |
3-3/4" |
10,000 Hours |
|
D 18-1S |
05-1340 |
5.8 Watts |
19-1/4" |
5" |
3-3/4" |
10,000 Hours |
|
D 24-1S |
05-1348 |
8.5 Watts |
25-1/4" |
5" |
3-3/4" |
10,000 Hours |
|
D 30-1S |
05-1352 |
11.2 Watts |
31-1/4" |
5" |
3-3/4" |
10,000 Hours |
|
D 36-1S |
05-1343 |
13.8 Watts |
37-1/4" |
5" |
3-3/4" |
10,000 Hours |
|
D 48-1S |
05-1334 |
19.3 Watts |
49-1/4" |
5" |
3-3/4" |
10,000 Hours |
|
D 64-1S |
05-1338A |
25.0 Watts |
65-1/4" |
5" |
3-3/4" |
10,000 Hours |
| |
|
|
|
|
|
|
|
D 18-2S |
(2) 05-1340 |
11.6 Watts |
19-1/4" |
6" |
3-3/4" |
10,000 Hours |
|
D 24-2S |
(2) 05-1348 |
17.0 Watts |
25-1/4" |
6" |
3-3/4" |
10,000 Hours |
|
D 30-2S |
(2) 05-1352 |
22.4 Watts |
31-1/4" |
6" |
3-3/4" |
10,000 Hours |
|
D 36-2S |
(2) 05-1343 |
27.6 Watts |
37-1/4" |
6" |
3-3/4" |
10,000 Hours |
|
D 48-2S |
(2) 05-1334 |
38.6 Watts |
49-1/4" |
6" |
3-3/4" |
10,000 Hours |
|
D 64-2S |
(2) 05-1338A |
50.0 Watts |
65-1/4" |
6" |
3-3/4" |
10,000 Hours |
1
Ultraviolet Output at 254 nanometers at 100 hours and 80
degrees F (approximate).
Lamp Data for the
SaniLight
uv air and surface irradiating fixtures
Lamp
No. |
Model
No. |
Lamp
Length |
Lamp & Holder
Length |
Power
Consumption1 |
Ultraviolet
Output 2 |
Rated Average
Effective Life |
|
05-1500 |
D 12 |
9-7/8" (250 mm) |
12" |
10 Watts |
3.1 Watts |
10,000 Hours |
|
05-1340 |
D 18 |
15-7/8" (403 mm) |
18" |
17 Watts |
5.8 Watts |
10,000 Hours |
|
05-1348 |
D 24 |
21-7/8" (556 mm) |
24" |
25 Watts |
8.5 Watts |
10,000 Hours |
|
05-1352 |
D 30 |
27-7/8" (708 mm) |
30" |
32 Watts |
11.2 Watts |
10,000 Hours |
|
05-1343 |
D 36 |
33-7/8" (860 mm) |
36" |
39 Watts |
13.8 Watts |
10,000 Hours |
|
05-1334 |
D 48 |
45-7/8" (1165 mm) |
48" |
50 Watts |
19.3 Watts |
10,000 Hours |
|
05-1338A |
D 64 |
61-7/8" (1572 mm) |
64" |
65 Watts |
25.0 Watts |
10,000 Hours |
|
1 Wattage is lamp watts only and does not
include ballast loss.
2 Ultraviolet Output at 254 nanometers at 100
hours and 80 degrees F (approximate). |
|
|
|
   
AeroLogic
uv air duct disinfection
units
-
Units are constructed of tough, corrosion-resistant 304 Stainless Steel to
insure long life
- Destroys airborne microbes including bacteria and virus in new
or existing forced air ducts systems
-
Units can be sized to provide up to a 98% bacteria kill rate
Applications: residential or commercial uses, homes, hospitals,
laboratories, new or existing forced air ducts systems, etc.
Advantages
of the
AeroLogic
uv air duct disinfection units
EFFECTIVE prevents excessive formation of
slime and mold growth on
heating/cooling coils, drip pans, etc., and consequent odors
ECONOMICAL
systems requires very little power to operate
SAFE no risk of over exposure
EASY simple installation and maintenance
AUTOMATIC continuous disinfection
without special attention or measurements
VERSATILE numerous units available to
handle various duct sizes and configurations
LOW MAINTENANCE annual lamp replacement
and periodic cleaning is all that is required
Special
Features of the
AeroLogic
uv air duct disinfection units
GERMICIDAL LAMPS - Genuine
Ster-L-Ray
ultraviolet germicidal lamps provide the utmost in quality, sustained high
output and long life.
Steadfast
LAMP HOLDERS are spring loaded telescopic type that facilitate
convenient, easy lamp change that is quick and hassle-free.
LAMP OPERATION INDICATOR is an
external monitor which indicates lamp failure in a fixture up to 25 feet
away.
STAINLESS STEEL CONSTRUCTION
The Stainless Steel housing provides unparalleled strength and durability.
The attractive brushed finish stands up to even the harshest environments.
OBSERVATION PORTS
A visible glow through the clear sight glass provides positive indication
of germicidal lamp operation.
An Observation Port in 1 or 2 inch sight glass assemblies is supplied with
each unit. This is to be installed in the duct wall for visual indication
of lamp operation.
The
AeroLogic
Air
Duct Disinfection units mount with universal standard bracket. The (2)
most common positions are shown below (units are perpendicular to air
flow). Many other mounting positions can be achieved with the universal
brackets that are included with each unit.
Fig. 1 Lamps
installed inside and ballast enclosure on outside of duct
Fig. 2 Whole unit
installed within duct
Specifications
of the Standard Models of the
AeroLogic
uv air duct disinfection
units
|
Model |
Lamp |
1 Total
Ultraviolet
Output |
Dimensions |
Rated
Average
Lamp Life |
Length
Partial Internal Mount |
Length
Full Internal Mount |
Width |
Height |
|
AD12-1 |
05-1500 |
3.1 Watts |
10-3/4" |
14-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD18-1 |
05-1340 |
5.8 Watts |
16-3/4" |
20-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD24-1 |
05-1348 |
8.5 Watts |
22-3/4" |
26-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD30-1 |
05-1352 |
11.2 Watts |
28-3/4" |
32-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD36-1 |
05-1343 |
13.8 Watts |
34-3/4" |
38-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD48-1 |
05-1334 |
19.3 Watts |
46-3/4" |
50-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD64-1 |
05-1338A |
25.0 Watts |
62-3/4" |
66-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD12-2 |
(2)05-1500 |
6.2 Watts |
10-3/4" |
14-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD18-2 |
(2)05-1340 |
11.6 Watts |
16-3/4" |
20-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD24-2 |
(2)05-1348 |
17.0 Watts |
22-3/4" |
26-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD30-2 |
(2)05-1352 |
22.4 Watts |
28-3/4" |
32-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD36-2 |
(2)05-1343 |
27.6 Watts |
34-3/4" |
38-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD48-2 |
(2)05-1334 |
38.6 Watts |
46-3/4" |
50-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD64-2 |
(2)05-1338A |
50.0 Watts |
62-3/4" |
66-1/4" |
3-1/2" |
20-3/8" |
10,000 Hrs. |
|
AD12-4 |
(4)05-1500 |
12.4 Watts |
10-3/4" |
14-13/16" |
7-3/8" |
17-1/4" |
10,000 Hrs. |
|
AD18-4 |
(4)05-1340 |
23.2 Watts |
16-3/4" |
20-13/16" |
7-3/8" |
17-1/4" |
10,000 Hrs. |
|
AD24-4 |
(4)05-1348 |
34.0 Watts |
22-3/4" |
26-13/16" |
7-3/8" |
17-1/4" |
10,000 Hrs. |
|
AD30-4 |
(4)05-1352 |
44.8 Watts |
28-3/4" |
32-13/16" |
7-3/8" |
17-1/4" |
10,000 Hrs. |
|
AD36-4 |
(4)05-1343 |
55.2 Watts |
34-3/4" |
38-13/16" |
7-3/8" |
17-1/4" |
10,000 Hrs. |
|
AD48-4 |
(4)05-1334 |
77.2 Watts |
46-3/4" |
50-13/16" |
7-3/8" |
17-1/4" |
10,000 Hrs. |
|
AD64-4 |
(4)05-1338A |
100.0 Watts |
62-3/4" |
66-13/16" |
7-3/8" |
17-1/4" |
10,000 Hrs. |
1 -
Output at 254 nanometers at 100 hours and 80 degrees F (approximate).
• 120 Volts 60 Hz and 220 Volts 50 Hz units are standard - specify when
ordering • Consult factory with other specific power requirements
Lamp Data
for the
AeroLogic
uv air duct disinfection
units
Lamp
No. |
Lamp
Length |
Lamp &
Holder Length |
1 Power
Consumption |
2
Ultraviolet
Output |
Rated
Average
Effective Life |
|
05-1500 |
9-7/8"
(251 mm) |
12" |
10 Watts |
| | |